Please use this identifier to cite or link to this item: http://repositorio.ineel.mx/jspui/handle/123456789/136
A comparative analysis of heating Indices of wells in Los Humeros, Puebla, México
GEORGINA IZQUIERDO MONTALVO
VICTOR MANUEL ARELLANO GOMEZ
ALFONSO ARAGON AGUILAR
Acceso Abierto
Conferencia
Inglés
12-Oct-2003
Drilling fluid circulation in a well alters the initial conditions of the reservoir. One such change is the thermal disturbance, whose magnitude is a function of formation characteristics. In this work we apply an analysis method, which uses temperature logs. The temperature is measured at fixed time periods after the drilling operations were stopped. This method uses the cooling caused by the fluid circulation during drilling to determine heating indices.
http://repositorio.ineel.mx/jspui/handle/123456789/136
Appears in Collections:Ponencias

Files in This Item:


File SizeFormat 
1021994.pdf558.08 kBAdobe PDFView/Open